Menu

Gaggenau 400 Series Vario Gas Cooktop 15'' Natural Gas 15 Mbar

Model# VG425211CA

Gaggenau400 Series Vario Gas Cooktop 15'' Natural Gas 15 Mbar
400 Series Vario Gas Cooktop 15'' Natural Gas 15 Mbar

Gaggenau 400 Series Vario Gas Cooktop 15'' Natural Gas 15 Mbar

Model # VG425211CA

For built-in appliances there are dozens of details that must be verified before we order or deliver your appliances. Your salesperson will contact you to review an extensive checklist prior to ordering to ensure all the bases are covered.

Special Order

Request a Quote

Style:
Gas
Height:
6 inches
Width:
15 inches
Depth:
20 inches
Number Of Burners:
2
Burner Type:
Open
Continuous Grate:
Yes
Convection Oven:
No
Down Draft:
No
Dual Fuel:
No
Ignition Type:
ELECTRONIC
Proof Mode:
No
Sabbath Mode:
No
Self Clean:
No
Storage Drawer:
No
Warming Drawer:
No
Wifi Enabled:
No


Cooktop type

Gas cooktop

Width (in.)

38 cm

Total number of cooktop burners

2

Power of the heating elements

1 x 2.0 KW, 1 x 4.0 KW

Basic surface material

brushed stainless steel

Frame type

Standard design

Variant color

Stainless steel

Energy efficiency of hob

58.5 %



Dimensions

158 x 380 x 520 mm

Minimum height for installation

134 mm

Maximum height for installation (in.)

134 mm

Minimum width for installation

359 mm

Maximum width for installation

361 mm

Depth for installation

491 mm



Previous Next Previous Next [{? it.layer }] [{?}] [{? it.layer }] [{?}]

Cooktop-based hood control

No



Watts

15 W

Gas connection rating

6,000 W

Fuse protection

15; 2 A

Volts

120 V

Power cord length

140 cm

Plug type

120V-3 prong

Gas type

Natural gas 15 mbar (USA)


Cooking zones

1 two-ring high output burner (570 - 13,600 BTU), suitable for pots up to max. 11".

1 two-ring standard output burner (570 - 6,800 BTU), suitable for pots up to max. 9 7/16".


Operation

Control knobs with illuminated
ring, cooking zone and output level markings.

One-handed operation.

Full electronic control in 12 output levels for exact power level regulation plus simmer function.

Automatic quick ignition.


Features

Simmer function.

Cast-iron pan support with flat, continuous pot surface.

Brass burner rings.


Safety

Electronic flame monitoring with automatic re-ignition.

Residual heat indicator.

Safety shut-off.


Planning notes

Depending on the type of installation - surface-/ or flush-mounted, with or without cover - the specific location of the control knob positions may vary.

If combining several Vario appliances of the 400 series, a connection strip VA 420 must be placed between the appliances. Depending on the type of installation, the corresponding connection strip must be provided.

The bearing capacity and stability,
in the case of thin countertops in particular, must be supported using suitable substructures. Take into account the appliance weight and additional loads.

Flush installation is possible in countertops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the edges must be observed. For other materials, please consult with your countertop manufacturer.

The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining.

The joint width may vary due to size tolerances of the combinations and of the countertop cut-out.

If installing several appliances in individual cut-outs allow for a division bar of inimum 1 " (50 mm) between the individual cut-outs.

The adjacent drawing "Installation of the control knob" must be observed if the panel is more than 1" thick. There must be a recess at the rear for proper electronic knob installation.

Plan for an electrical connection (the appliance is not operable without power supply).

Air intake from above.

No intermediate shelf required.

The rear panel must consist of a non-flammable material. Wall trims must be resistant to heat.

The minimum distance from the side of appliance edge to the wall or furnishing components must be at least 6".

When used with VL 414 downdraft ventilation, the air deflector AA 414 is recommended to ensure maximum permance of the cooktop.

Minimum distance between gas cooktop(s) with more than 37,533 BTU (11kW) and ventilation hood must be 30" (76cm).

Appliance can be snapped into the worktop from above.


Rating

Total Amps: 15 A.

120 V / 60 Hz.

Connecting cable 55" (1.4 m) with plug.

Show All Technical Information
Instruction manualClick here to download
Instruction manualClick here to download
Instruction manualClick here to download
Installation InstructionClick here to download
Installation InstructionClick here to download
Installation InstructionClick here to download
Installation InstructionClick here to download
Product specification sheet.Click here to download
Further installation informationClick here to download
Further installation informationClick here to download
Warranty servicesClick here to download
WarrantyClick here to download

Enter Your Review:

Fields marked with an asterisk (*) are required.

Overall Rating
Features
Design
Value
Rating Legend: 5 Stars = Excellent, 4 Stars = Good, 3 Stars = Average, 2 Stars = Fair, 1 Star = Poor
Example: Best Purchase Ever
Review should be at least 50 characters
Example: Your City, State
We will use this email address provided to contact you if we have questions regarding your review. It will not be made public.

CALIFORNIA RESIDENTS ONLY - WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

There was a problem submitting the form.

Please correct the following errors and try again.

Product Inquiry Form

Fields marked with an asterisk (*) are required.

Optional Information
Captcha

Added to Cart

Start Checkout Continue Shopping

Final discounts, tax, and shipping costs at checkout.

Added to Quote
Model#
Final discounts, tax, and shipping costs at checkout.